{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2012-4690","published":"2012-12-08T15:55:01.007000Z","last_modified":"2026-06-16T23:45:35.173000Z","status":"Modified","cvss":{"version":"2.0","score":7.1,"severity":"HIGH","vector":"AV:N/AC:M/Au:N/C:N/I:N/A:C","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-16"],"cpes":[{"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"ab_micrologix_controller","version":"1100"},{"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1200:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"ab_micrologix_controller","version":"1200"},{"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"ab_micrologix_controller","version":"1400"},{"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1500:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"ab_micrologix_controller","version":"1500"},{"criteria":"cpe:2.3:h:rockwellautomation:plc-5_controller:-:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"plc-5_controller"},{"criteria":"cpe:2.3:h:rockwellautomation:slc_500_controller:-:*:*:*:*:*:*:*","part":"h","vendor":"rockwellautomation","product":"slc_500_controller"}],"cpes_truncated":false,"vendors":["rockwellautomation"],"products":["rockwellautomation/ab_micrologix_controller","rockwellautomation/plc-5_controller","rockwellautomation/slc_500_controller"],"cat":"firmware","platform":"appliance","eol":false,"severity":"high","priority_score":58,"links":{"html_es":"/es/cve/CVE-2012-4690/","html_en":"/en/cve/CVE-2012-4690/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2012-4690","cve_org":"https://www.cve.org/CVERecord?id=CVE-2012-4690"},"untrusted":{"vendor_name":"Rockwellautomation","product_name":"Ab Micrologix Controller","desc_en":"Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits.","affected":[],"references":[{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A","tags":[]},{"url":"http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf","tags":["US Government Resource"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407","tags":[]}]}}