{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2016-2846","published":"2016-03-16T10:59:04.277000Z","last_modified":"2026-06-17T00:44:34.863000Z","status":"Modified","cvss":{"version":"3.0","score":6.5,"severity":"MEDIUM","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-254"],"cpes":[{"criteria":"cpe:2.3:o:siemens:simatic_s7_cpu_1200_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_s7_cpu_1200_firmware","version_end_including":"3.0.2"}],"cpes_truncated":false,"vendors":["siemens"],"products":["siemens/simatic_s7_cpu_1200_firmware"],"epss":{"score":0.01691,"percentile":0.7752,"date":"2026-11-27","model_version":"v2026.06.15"},"cat":"firmware","platform":"appliance","eol":false,"packages":[],"severity":"medium","priority_score":54,"links":{"html_es":"/es/cve/CVE-2016-2846/","html_en":"/en/cve/CVE-2016-2846/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2016-2846","cve_org":"https://www.cve.org/CVERecord?id=CVE-2016-2846"},"untrusted":{"vendor_name":"Siemens","product_name":"Simatic S7 Cpu 1200 Firmware","desc_en":"Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a \"user program block\" protection mechanism via unspecified vectors.","affected":[],"references":[{"url":"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf","tags":[]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01","tags":[]}]}}