{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2017-5689","published":"2017-05-02T14:59:00.520000Z","last_modified":"2026-06-17T01:21:02.563000Z","status":"Analyzed","cvss":{"version":"3.1","score":9.8,"severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-269"],"cpes":[{"criteria":"cpe:2.3:o:hpe:proliant_ml10_gen9_server_firmware:5.0:*:*:*:*:*:*:*","part":"o","vendor":"hpe","product":"proliant_ml10_gen9_server_firmware","version":"5.0"},{"criteria":"cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_itp1000_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc847d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc847c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc847c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc827d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc827c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc827c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc677d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc677c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc677c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc647d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc647c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc647c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc627d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc627c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc627c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc547g_firmware","version_end_excluding":"11.0.26.3000"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc547e_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc547d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc547d_firmware","version_end_excluding":"7.1.91.3272"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc477e_firmware","version_end_excluding":"21.01.05"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc477d_firmware:-:*:*:*:-:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc477d_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc477d_firmware:-:*:*:*:pro:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc477d_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_field_pg_m3_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_field_pg_m3_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_field_pg_m4_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_field_pg_m4_firmware","version_end_excluding":"18.01.06"},{"criteria":"cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_field_pg_m5_firmware","version_end_excluding":"22.01.03"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc427e_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc427e_firmware","version_end_excluding":"21.01.04"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc547d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc547d_firmware","version_end_excluding":"7.1.91.3272"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc547e_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc547e_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc547g_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc547g_firmware","version_end_excluding":"11.0.26.3000"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc627c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc627c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc677c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc677c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc647c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc647c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc647d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc647d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc847c_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc847c_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc847d_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc847d_firmware","version_end_excluding":"9.1.41.3024"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc427e_firmware:-:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc427e_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_pcs_7_ipc477d_firmware:-:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_pcs_7_ipc477d_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc427d_firmware:-:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc427d_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_ipc427e_firmware","version_end_excluding":"21.01.05"},{"criteria":"cpe:2.3:o:siemens:simotion_p320-4_s_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simotion_p320-4_s_firmware","version_end_excluding":"17.02.06.83.1"},{"criteria":"cpe:2.3:o:siemens:sinumerik_pcu50.5-p_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"sinumerik_pcu50.5-p_firmware","version_end_excluding":"6.2.61.3535"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:6.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"6.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:6.1:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"6.1"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:6.2:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"6.2"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:7.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"7.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:7.1:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"7.1"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:8.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"8.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:8.1:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"8.1"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:9.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"9.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:9.1:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"9.1"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:9.5:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"9.5"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:10.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"10.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:11.0:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"11.0"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:11.5:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"11.5"},{"criteria":"cpe:2.3:o:intel:active_management_technology_firmware:11.6:*:*:*:*:*:*:*","part":"o","vendor":"intel","product":"active_management_technology_firmware","version":"11.6"}],"cpes_truncated":false,"vendors":["hpe","siemens","intel"],"products":["hpe/proliant_ml10_gen9_server_firmware","siemens/simatic_itp1000_firmware","siemens/simatic_ipc847d_firmware","siemens/simatic_ipc847c_firmware","siemens/simatic_ipc827d_firmware","siemens/simatic_ipc827c_firmware","siemens/simatic_ipc677d_firmware","siemens/simatic_ipc677c_firmware","siemens/simatic_ipc647d_firmware","siemens/simatic_ipc647c_firmware","siemens/simatic_ipc627d_firmware","siemens/simatic_ipc627c_firmware","siemens/simatic_ipc547g_firmware","siemens/simatic_ipc547e_firmware","siemens/simatic_ipc547d_firmware","siemens/simatic_ipc477e_firmware","siemens/simatic_ipc477d_firmware","siemens/simatic_field_pg_m3_firmware","siemens/simatic_field_pg_m4_firmware","siemens/simatic_field_pg_m5_firmware","siemens/simatic_pcs_7_ipc427e_firmware","siemens/simatic_pcs_7_ipc547d_firmware","siemens/simatic_pcs_7_ipc547e_firmware","siemens/simatic_pcs_7_ipc547g_firmware","siemens/simatic_pcs_7_ipc627c_firmware","siemens/simatic_pcs_7_ipc677c_firmware","siemens/simatic_pcs_7_ipc647c_firmware","siemens/simatic_pcs_7_ipc647d_firmware","siemens/simatic_pcs_7_ipc847c_firmware","siemens/simatic_pcs_7_ipc847d_firmware","siemens/simatic_pcs_7_ipc477d_firmware","siemens/simatic_ipc427d_firmware","siemens/simatic_ipc427e_firmware","siemens/simotion_p320-4_s_firmware","siemens/sinumerik_pcu50.5-p_firmware","intel/active_management_technology_firmware"],"ssvc":{"exploitation":"active","automatable":"yes","technical_impact":"total"},"kev":{"date_added":"2022-01-28","due_date":"2022-07-28","ransomware":false,"forensic_triage":false,"cwes":[]},"epss":{"score":0.92189,"percentile":0.99886,"date":"2026-11-28","model_version":"v2026.06.15"},"cat":"firmware","platform":"multi","eol":false,"packages":[],"severity":"critical","priority_score":83,"links":{"html_es":"/es/cve/CVE-2017-5689/","html_en":"/en/cve/CVE-2017-5689/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-5689","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-5689"},"untrusted":{"vendor_name":"Intel","product_name":"Active Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability","desc_en":"An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).","affected":[{"untrusted_vendor":"Intel Corporation","untrusted_product":"Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability"}],"kev":{"vendor":"Intel","product":"Active Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability","name":"Intel Active Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability Privilege Escalation Vulnerability","desc":"Intel products contain a vulnerability which can allow attackers to perform privilege escalation.","action":"Apply updates per vendor instructions.","notes":"https://nvd.nist.gov/vuln/detail/CVE-2017-5689"},"ai":{"model":"us.anthropic.claude-haiku-4-5-20251001-v1:0","prompt_version":"2","input_hash":"84f452bfe54eb611e80d6d333d9281b5","generated":"2026-11-26T20:16:34.179673Z","es":{"untrusted_title":"Escalada de privilegios en Intel Active Management Technology (AMT) y tecnologí…","untrusted_summary":"Intel Active Management Technology (AMT), Standard Manageability (ISM) y Small Business Technology (SBT) contienen una vulnerabilidad de escalada de privilegios. Un atacante sin autenticación en la red puede obtener privilegios del sistema en SKUs de mantenibilidad provisionados, o un atacante local sin privilegios puede provisionar características de mantenibilidad. CISA confirmó esta vulnerabilidad como explotada en la naturaleza."},"en":{"untrusted_title":"Privilege Escalation in Intel Active Management Technology (AMT) and Manageabil…","untrusted_summary":"Intel Active Management Technology (AMT), Standard Manageability (ISM), and Small Business Technology (SBT) contain a privilege escalation vulnerability. An unauthenticated network attacker can gain system privileges on provisioned manageability SKUs, or an unprivileged local attacker can provision manageability features. CISA confirmed this vulnerability as exploited in the wild."},"remediation":{"status":"fix","fixed_versions":["9.1.41.3024","6.2.61.3535"],"untrusted_action_es":"Actualiza el firmware de Intel AMT, ISM o SBT a la versión corregida proporcionada por tu fabricante de hardware (HPE, Siemens u otro). Consulta el aviso de Intel para obtener parches específicos.","untrusted_action_en":"Update Intel AMT, ISM, or SBT firmware to the patched version provided by your hardware manufacturer (HPE, Siemens, or other). Refer to Intel's advisory for specific patches.","vendor_url":"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075&languageid=en-fr"},"reviewed":false},"references":[{"url":"http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html","tags":["Patch","Third Party Advisory"]},{"url":"http://www.securityfocus.com/bid/98269","tags":["Broken Link","Third Party Advisory","VDB Entry"]},{"url":"http://www.securitytracker.com/id/1038385","tags":["Broken Link","Third Party Advisory","VDB Entry"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf","tags":["Third Party Advisory"]},{"url":"https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf","tags":["Broken Link"]},{"url":"https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03754en_us","tags":["Third Party Advisory"]},{"url":"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075&languageid=en-fr","tags":["Patch","Vendor Advisory"]},{"url":"https://security.netapp.com/advisory/ntap-20170509-0001/","tags":["Third Party Advisory"]},{"url":"https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf","tags":["Broken Link","Exploit","Technical Description","Third Party Advisory"]},{"url":"https://www.embedi.com/news/mythbusters-cve-2017-5689","tags":["Broken Link","Third Party Advisory"]},{"url":"https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability","tags":["Technical Description","Third Party Advisory"]},{"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-5689","tags":["US Government Resource"]}]}}