{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2017-6780","published":"2017-09-07T21:29:00.740000Z","last_modified":"2026-06-17T01:23:05.187000Z","status":"Modified","cvss":{"version":"3.0","score":7.5,"severity":"HIGH","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-399","CWE-770"],"cpes":[{"criteria":"cpe:2.3:a:cisco:connected_grid_network_management_system:*:*:*:*:*:*:*:*","part":"a","vendor":"cisco","product":"connected_grid_network_management_system","version_end_including":"3.0\\(0.54\\)"},{"criteria":"cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*","part":"a","vendor":"cisco","product":"iot_field_network_director","version_end_including":"3.2.0-182"}],"cpes_truncated":false,"vendors":["cisco"],"products":["cisco/connected_grid_network_management_system","cisco/iot_field_network_director"],"epss":{"score":0.01738,"percentile":0.78182,"date":"2026-11-28","model_version":"v2026.06.15"},"cat":"network","platform":"appliance","eol":false,"packages":[],"severity":"high","priority_score":60,"links":{"html_es":"/es/cve/CVE-2017-6780/","html_en":"/en/cve/CVE-2017-6780/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6780","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6780"},"untrusted":{"vendor_name":"Cisco","product_name":"Connected Grid Network Management System","desc_en":"A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.","affected":[],"references":[{"url":"http://www.securityfocus.com/bid/100641","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd","tags":["Vendor Advisory"]}]}}