{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2017-7915","published":"2017-05-29T16:29:00.210000Z","last_modified":"2026-06-17T01:25:28.237000Z","status":"Modified","cvss":{"version":"3.0","score":9.8,"severity":"CRITICAL","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-307"],"cpes":[{"criteria":"cpe:2.3:o:moxa:oncell_g3110-hspa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_g3110-hspa_firmware","version_end_including":"1.3"},{"criteria":"cpe:2.3:o:moxa:oncell_g3110-hsdpa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_g3110-hsdpa_firmware","version_end_including":"1.2"},{"criteria":"cpe:2.3:o:moxa:oncell_g3150-hsdpa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_g3150-hsdpa_firmware","version_end_including":"1.4"},{"criteria":"cpe:2.3:o:moxa:oncell_5104-hsdpa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_5104-hsdpa_firmware","version_end_including":"-"},{"criteria":"cpe:2.3:o:moxa:oncell_5104-hspa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_5104-hspa_firmware","version_end_including":"-"},{"criteria":"cpe:2.3:o:moxa:oncell_5004-hspa_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"moxa","product":"oncell_5004-hspa_firmware","version_end_including":"-"}],"cpes_truncated":false,"vendors":["moxa"],"products":["moxa/oncell_g3110-hspa_firmware","moxa/oncell_g3110-hsdpa_firmware","moxa/oncell_g3150-hsdpa_firmware","moxa/oncell_5104-hsdpa_firmware","moxa/oncell_5104-hspa_firmware","moxa/oncell_5004-hspa_firmware"],"epss":{"score":0.01532,"percentile":0.75141,"date":"2026-11-28","model_version":"v2026.06.15"},"cat":"firmware","platform":"appliance","eol":false,"packages":[],"severity":"critical","priority_score":74,"links":{"html_es":"/es/cve/CVE-2017-7915/","html_en":"/en/cve/CVE-2017-7915/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-7915","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-7915"},"untrusted":{"vendor_name":"Moxa","product_name":"Oncell G3110-hspa Firmware","desc_en":"An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.","affected":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-143-01","tags":["US Government Resource"]}]}}