{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2022-32513","published":"2023-01-30T23:15:09.927000Z","last_modified":"2026-06-17T04:47:27.140000Z","status":"Modified","cvss":{"version":"3.1","score":9.8,"severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"nvd@nist.gov","primary":true},"auth":false,"cwes":["CWE-521"],"cpes":[{"criteria":"cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"5500ac2_firmware","version_end_excluding":"1.11.0"},{"criteria":"cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"5500nac_firmware","version_end_excluding":"1.11.0"},{"criteria":"cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"5500nac2_firmware","version_end_excluding":"1.11.0"},{"criteria":"cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"5500shac_firmware","version_end_excluding":"1.11.0"},{"criteria":"cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"lss5500nac_firmware","version_end_excluding":"1.11.0"},{"criteria":"cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"schneider-electric","product":"lss5500shac_firmware","version_end_excluding":"1.11.0"}],"cpes_truncated":false,"vendors":["schneider-electric"],"products":["schneider-electric/5500ac2_firmware","schneider-electric/5500nac_firmware","schneider-electric/5500nac2_firmware","schneider-electric/5500shac_firmware","schneider-electric/lss5500nac_firmware","schneider-electric/lss5500shac_firmware"],"ssvc":{"exploitation":"none","automatable":"yes","technical_impact":"total"},"epss":{"score":0.00919,"percentile":0.58527,"date":"2026-11-29","model_version":"v2026.06.15"},"cat":"firmware","platform":"appliance","eol":false,"packages":[],"severity":"critical","priority_score":74,"links":{"html_es":"/es/cve/CVE-2022-32513/","html_en":"/en/cve/CVE-2022-32513/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-32513","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-32513"},"untrusted":{"vendor_name":"Schneider-electric","product_name":"5500ac2 Firmware","desc_en":"A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)","affected":[{"untrusted_vendor":"Schneider Electric","untrusted_product":"C-Bus Network Automation Controller, LSS5500NAC"},{"untrusted_vendor":"Schneider Electric","untrusted_product":"Wiser for C-Bus Automation Controller, LSS5500SHAC"},{"untrusted_vendor":"Schneider Electric","untrusted_product":"Clipsal C-Bus Network Automation Controller, 5500NAC"},{"untrusted_vendor":"Schneider Electric","untrusted_product":"Clipsal Wiser for C-Bus Automation Controller, 5500SHAC"},{"untrusted_vendor":"Schneider Electric","untrusted_product":"SpaceLogic C-Bus Network Automation Controller, 5500NAC2"},{"untrusted_vendor":"Schneider Electric","untrusted_product":"SpaceLogic C-Bus Application Controller, 5500AC2"}],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf","tags":["Patch","Vendor Advisory"]}]}}