{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2022-34821","published":"2022-07-12T10:15:12.393000Z","last_modified":"2026-09-03T01:15:22.797000Z","status":"Modified","cvss":{"version":"4.0","score":8.8,"severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","source":"productcert@siemens.com","primary":false},"auth":true,"cwes":["CWE-94"],"cpes":[{"criteria":"cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1242-7_v2_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1243-1_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1243-7_lte_eu_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1243-7_lte_us_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1243-8_irc_firmware"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1542sp-1_irc_firmware","version_start_including":"2.0"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1543-1_firmware","version_end_excluding":"3.0.22"},{"criteria":"cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"simatic_cp_1543sp-1_firmware","version_start_including":"2.0"},{"criteria":"cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware","version_start_including":"2.0"},{"criteria":"cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_et_200sp_cp_1543sp-1_isec_firmware","version_start_including":"2.0"},{"criteria":"cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware","version_start_including":"2.0"},{"criteria":"cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_net_cp_1242-7_v2_firmware"},{"criteria":"cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_net_cp_1543-1_firmware","version_end_excluding":"3.0.22"},{"criteria":"cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_s7-1200_cp_1243-1_firmware"},{"criteria":"cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"siemens","product":"siplus_s7-1200_cp_1243-1_rail_firmware"}],"cpes_truncated":false,"vendors":["siemens"],"products":["siemens/simatic_cp_1242-7_v2_firmware","siemens/simatic_cp_1243-1_firmware","siemens/simatic_cp_1243-7_lte_eu_firmware","siemens/simatic_cp_1243-7_lte_us_firmware","siemens/simatic_cp_1243-8_irc_firmware","siemens/simatic_cp_1542sp-1_irc_firmware","siemens/simatic_cp_1543-1_firmware","siemens/simatic_cp_1543sp-1_firmware","siemens/siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware","siemens/siplus_et_200sp_cp_1543sp-1_isec_firmware","siemens/siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware","siemens/siplus_net_cp_1242-7_v2_firmware","siemens/siplus_net_cp_1543-1_firmware","siemens/siplus_s7-1200_cp_1243-1_firmware","siemens/siplus_s7-1200_cp_1243-1_rail_firmware"],"ssvc":{"exploitation":"none","automatable":"no","technical_impact":"total"},"cat":"firmware","platform":"appliance","eol":false,"packages":[],"severity":"high","priority_score":53,"links":{"html_es":"/es/cve/CVE-2022-34821/","html_en":"/en/cve/CVE-2022-34821/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-34821","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-34821"},"untrusted":{"vendor_name":"Siemens","product_name":"Simatic Cp 1242-7 V2 Firmware","desc_en":"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.","affected":[{"untrusted_vendor":"Siemens","untrusted_product":"RUGGEDCOM RM1224 LTE(4G) EU"},{"untrusted_vendor":"Siemens","untrusted_product":"RUGGEDCOM RM1224 LTE(4G) NAM"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M804PB"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M812-1 ADSL-Router"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M816-1 ADSL-Router"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M826-2 SHDSL-Router"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M874-2"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M874-3"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M876-3"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M876-3 (ROK)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M876-4"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M876-4 (EU)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE M876-4 (NAM)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE MUM853-1 (EU)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE MUM856-1 (EU)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE MUM856-1 (RoW)"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE S615 EEC LAN-Router"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE S615 LAN-Router"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE SC622-2C"},{"untrusted_vendor":"Siemens","untrusted_product":"SCALANCE SC626-2C"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-413565.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-517377.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf","tags":["Patch","Vendor Advisory"]}]}}