{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2023-25914","published":"2023-08-21T21:15:08.970000Z","last_modified":"2026-11-26T05:17:48.717000Z","status":"Modified","cvss":{"version":"3.1","score":8.8,"severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"nvd@nist.gov","primary":true},"auth":true,"cwes":["CWE-22"],"cpes":[{"criteria":"cpe:2.3:o:danfoss:ak-sm_800a_firmware:*:*:*:*:*:*:*:*","part":"o","vendor":"danfoss","product":"ak-sm_800a_firmware","version_end_including":"3.3"}],"cpes_truncated":false,"vendors":["danfoss"],"products":["danfoss/ak-sm_800a_firmware"],"ssvc":{"exploitation":"active","automatable":"no","technical_impact":"total"},"kev":{"date_added":"2026-11-25","due_date":"2026-11-28","ransomware":false,"forensic_triage":true,"cwes":["CWE-22"]},"cat":"firmware","platform":"appliance","eol":false,"severity":"high","priority_score":62,"links":{"html_es":"/es/cve/CVE-2023-25914/","html_en":"/en/cve/CVE-2023-25914/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-25914","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-25914"},"untrusted":{"vendor_name":"Danfoss","product_name":"AK-SM 800A Series","desc_en":"Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise.","affected":[{"untrusted_vendor":"Danfoss","untrusted_product":"AK-SM800A"}],"kev":{"vendor":"Danfoss","product":"AK-SM 800A Series","name":"Danfoss AK-SM 800A Series Path Traversal Vulnerability","desc":"Danfoss AK-SM 800A Series contains a path traversal vulnerability that could allow an attacker to access and read underlying server system files via the XML interface.","action":"Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.","notes":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2023-08-01 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2023-25914"},"ai":{"model":"us.anthropic.claude-sonnet-4-6","prompt_version":"2","input_hash":"fd2f8ce377d3920c04a8cdd9530d4e4b","generated":"2026-11-26T18:32:54.836878Z","es":{"untrusted_title":"Path Traversal con autenticación en Danfoss AK-SM 800A Series","untrusted_summary":"Los dispositivos Danfoss AK-SM 800A con firmware hasta 3.3 son vulnerables a path traversal vía la interfaz XML. Un atacante autenticado puede leer archivos del sistema subyacente, lo que puede derivar en un compromiso total del sistema. CISA la ha confirmado como explotada activamente."},"en":{"untrusted_title":"Authenticated Path Traversal in Danfoss AK-SM 800A Series","untrusted_summary":"Danfoss AK-SM 800A devices with firmware up to 3.3 are vulnerable to path traversal via the XML interface. An authenticated attacker can read underlying server system files, potentially leading to full system compromise. CISA has confirmed active exploitation in the wild."},"remediation":{"status":"workaround","fixed_versions":[],"untrusted_action_es":"Aplica las mitigaciones del fabricante según las instrucciones de CISA. Si no hay mitigaciones disponibles, considera discontinuar el uso del producto.","untrusted_action_en":"Apply vendor mitigations per CISA instructions. If mitigations are unavailable, consider discontinuing use of the product.","vendor_url":"https://csirt.divd.nl/DIVD-2023-00025"},"reviewed":false},"references":[{"url":"https://csirt.divd.nl/CVE-2023-25914","tags":["Third Party Advisory"]},{"url":"https://csirt.divd.nl/DIVD-2023-00025","tags":["Third Party Advisory"]},{"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-25914","tags":[]}],"news":[{"source":"Cyber Security News","published":"2026-11-26T14:09:18+00:00","url":"https://cybersecuritynews.com/cisa-adds-10-flaws-to-kev/","title":"CISA Adds 10 Flaws from Danfoss, HPE, Mitel MiCollab and Vates Xen to Exploited Catalog","summary":"The U.S. Cybersecurity and Infrastructure Security Agency (CISA) added 10 vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog on November 25, 2026, after finding evidence of active exploitation. Five affect Mitel MiCollab, three affect Danfoss refrigeration controllers, and the remaining two affect HPE Juniper networking products and Vates Xen Orchestra. The CISA alert does not […"},{"source":"Security Affairs","published":"2026-11-26T06:05:09+00:00","url":"https://securityaffairs.com/204014/hacking/u-s-cisa-adds-hpe-juniper-session-smart-conductor-and-session-smart-router-flaw-to-its-known-exploited-vulnerabilities-catalog.html","title":"U.S. CISA adds HPE, Danfoss, Mitel MiCollab, and Vates Xen Orchestra flaws to its Known Exploited Vulnerabilities catalog","summary":"U.S. Cybersecurity and Infrastructure Security Agency (CISA) adds HPE, Danfoss, Mitel MiCollab, and Vates Xen Orchestra flaws to its Known Exploited Vulnerabilities catalog. The U.S. Cybersecurity and Infrastructure Security Agency (CISA) added the following HPE, Danfoss, Mitel MiCollab, and Vates Xen Orchestra flaws to its Known Exploited Vulnerabilities (KEV) catalog. The first flaw, tracked as…"}]},"social":{"people":1,"posts":1,"window_days":30}}