{"schema":"/api/v1/schema/cve.json","api_version":"1","id":"CVE-2025-9313","published":"2025-10-28T12:15:42.967000Z","last_modified":"2026-10-08T11:10:00.250000Z","status":"Deferred","cvss":{"version":"4.0","score":9.3,"severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","source":"cvd@cert.pl","primary":false},"auth":false,"cwes":["CWE-288"],"cpes":[],"cpes_truncated":false,"vendors":["asseco-poland-s.a"],"products":["asseco-poland-s.a/mmedica"],"ssvc":{"exploitation":"none","automatable":"yes","technical_impact":"total"},"cat":"app","platform":"multi","eol":false,"packages":[],"severity":"critical","priority_score":71,"links":{"html_es":"/es/cve/CVE-2025-9313/","html_en":"/en/cve/CVE-2025-9313/","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-9313","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-9313"},"untrusted":{"vendor_name":"Asseco Poland S.A.","product_name":"mMedica","desc_en":"An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5.","affected":[{"untrusted_vendor":"Asseco Poland S.A.","untrusted_product":"mMedica"}],"references":[{"url":"https://cert.pl/en/posts/2025/10/CVE-2025-9313/","tags":[]},{"url":"https://mmedica.asseco.pl/","tags":[]}]}}