Live threats

All CVEs / Siemens

CVE-2011-4876Siemens Wincc Flexible

Critical 9.3 No auth needed

Priority
72
CVSS 2.0
9.3
EPSS
9.0%
probability of exploitation in 30 days · percentile 96
Auth required
No
Published
Feb 3, 2012
Updated
Jun 16, 2026
Category
Application · Cross-platform
Weakness (CWE)
CWE-22
Vector
AV:N/AC:M/Au:N/C:C/I:C/A:C

What happens

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.

Original NVD text.

What to do

  1. Apply the vendor's security update for Wincc Flexible.
  2. It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.

Affected products (CPE)

VendorProductVersions
siemenswincc_flexible2004
siemenswincc_flexible2005
siemenswincc_flexible2007
siemenswincc_flexible2008
siemenswinccv11
siemenssimatic_hmi_panelscomfort_panels
siemenssimatic_hmi_panelsmobile_panels
siemenssimatic_hmi_panelsmp
siemenssimatic_hmi_panelsop
siemenssimatic_hmi_panelstp
siemenswincc_runtime_advancedv11
siemenswincc_flexible_runtimeall

Official sources

References

Links published by the sources. Open them with care.