Live threats
VulnFox

All CVEs / Ni

CVE-2013-5021Ni Labview

Critical 9.3 No auth needed

Priority
71
CVSS 2.0
9.3
EPSS
—
Auth required
No
Published
Aug 6, 2013
Updated
Jun 16, 2026
Category
Application · Cross-platform
Weakness (CWE)
CWE-22
Vector
AV:N/AC:M/Au:N/C:C/I:C/A:C

What happens

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

Original NVD text.

What to do

  1. Apply the vendor's security update for Labview.
  2. It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.

Affected products (CPE)

VendorProductVersions
nilabview≤ 2012
nilabwindows≤ 2012
nimeasurementstudio≤ 2013
niteststand≤ 2012
abbdatamanager1.0.0
abbdatamanager6.3.6

Official sources

References

Links published by the sources. Open them with care.