CVE-2016-9335Redlion Sixnet-managed Industrial Switches Firmware
Critical 10.0 No auth needed
Follow: this CVE · Redlion · Redlion Sixnet-managed Industrial Switches Firmware We alert you by email or Slack (account required).
- Priority
- 75
- CVSS 3.0
- 10.0
- EPSS
- 1.5% probability of exploitation in 30 days · percentile 75
- Auth required
- No
- Published
- May 9, 2018
- Updated
- Jun 17, 2026
- Category
- Firmware · Network appliance
- Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
What happens
A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.
What to do
- Apply the vendor's security update for Sixnet-managed Industrial Switches Firmware.
- It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.
Affected products (CPE)
| Vendor | Product | Versions |
|---|---|---|
| redlion | sixnet-managed_industrial_switches_firmware | ≤ 5.0.196 |
| redlion | stride-managed_ethernet_switches_firmware | ≤ 5.0.190 |
Official sources
References
Links published by the sources. Open them with care.
- ics-cert.us-cert.gov Third Party Advisory US Government Resource