CVE-2023-0321Campbellsci Cr6 Firmware
Critical 9.1 No auth needed
Follow: this CVE · Campbellsci · Campbellsci Cr6 Firmware We alert you by email or Slack (account required).
- Priority
- 70
- CVSS 3.1
- 9.1
- EPSS
- —
- Auth required
- No
- Published
- Jan 26, 2023
- Updated
- Jun 17, 2026
- Category
- Firmware · Network appliance
- Weakness (CWE)
- CWE-200
- SSVC (CISA)
- Exploitation: proof of concept · Automatable: yes · Technical impact: partial
- Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
What happens
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
What to do
- Apply the vendor's security update for Cr6 Firmware.
- It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.
Affected products (CPE)
| Vendor | Product | Versions |
|---|---|---|
| campbellsci | cr6_firmware | all |
| campbellsci | cr300_firmware | all |
| campbellsci | cr800_firmware | all |
| campbellsci | cr1000_firmware | all |
| campbellsci | cr3000_firmware | all |
Official sources
References
Links published by the sources. Open them with care.
- www.hackplayers.com Exploit Third Party Advisory
- www.incibe-cert.es Mitigation Third Party Advisory