CVE-2025-41450Danfoss AK-SM 800A Series
Improper Authentication in Danfoss AK-SM 800A Series
High 7.5 KEV No auth neededRecent
- Priority
- 70
- CVSS 3.1
- 7.5
- EPSS
- —
- Auth required
- No
- In KEV since
- Nov 25, 2026
- CISA deadline
- Dec 9, 2026
- Ransomware use
- Unknown
- Published
- May 8, 2025
- Updated
- Nov 26, 2026
- Category
- Firmware · Network appliance
- Weakness (CWE)
- CWE-305
- SSVC (CISA)
- Exploitation: active · Automatable: no · Technical impact: partial
- Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
What happens
Danfoss AK-SM 800A Series firmware prior to version 4.2 contains an improper authentication flaw. An unauthenticated remote attacker can generate a web report exposing sensitive data such as internal IP addresses, usernames, and store names. CISA has confirmed active exploitation in the wild.
AI-generated summary (Claude) based on NVD and CISA data. Not reviewed yet: check the details in the vendor advisory.
Show the original NVD text
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2
Exploitation confirmed by CISA
Danfoss AK-SM 800A Series contains an improper authentication vulnerability that could allow an attacker to generate a web report exposing sensitive information, including internal IP addresses, usernames, and store names.
Action required by CISA: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
What to do
Patch available · fixed versions: 4.2
Update the Danfoss AK-SM 800A Series firmware to version 4.2 or later following vendor instructions.
Vendor advisory · www.danfoss.com ↗
AI-generated from public data; not reviewed.
- Apply the vendor's security update for AK-SM 800A Series.
- CISA has confirmed it is exploited: treat it as urgent. The deadline for US federal agencies is December 9, 2026.
- It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.
- Check logs for signs of earlier exploitation.
Affected products (CPE)
| Vendor | Product | Versions |
|---|---|---|
| danfoss | ak-sm_800a_firmware | < 4.2 |
In the news
- CISA Adds 10 Flaws from Danfoss, HPE, Mitel MiCollab and Vates Xen to Exploited Catalog · Cyber Security News · Nov 26, 2026
- U.S. CISA adds HPE, Danfoss, Mitel MiCollab, and Vates Xen Orchestra flaws to its Known Exploited Vulnerabilities catalog · Security Affairs · Nov 26, 2026
- Un ciberataque apaga vitrinas frigoríficas en supermercados franceses · Una al Día (Hispasec) · Oct 14, 2026
Security media stories that mention this CVE. Titles unmodified.
On social media
5 people and 5 posts on Bluesky in the last 30 days.
Most recent posts, without bots or automated feeds. The text belongs to its authors. Search on Bluesky
Official sources
References
Links published by the sources. Open them with care.
- www.danfoss.com Vendor Advisory
- github.com Exploit Third Party Advisory
- www.cisa.gov