Live threats

All CVEs / Wertheim GmbH

CVE-2026-34021Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)

High 8.6 No auth needed

Priority
67
CVSS 4.0
8.6
EPSS
—
Auth required
No
Published
Jun 15, 2026
Updated
Oct 25, 2026
Category
Application · Cross-platform
Weakness (CWE)
CWE-294
SSVC (CISA)
Exploitation: proof of concept · Automatable: no · Technical impact: total
Vector
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

What happens

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

Original NVD text.

What to do

  1. Apply the vendor's security update for Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller).
  2. It can be exploited without authentication: if you cannot patch now, restrict Internet access to the affected service.

Affected products

As reported by the CNA that published the CVE. NVD has not added CPEs with versions yet.

Official sources

References

Links published by the sources. Open them with care.