CVE-2017-7574Schneider-electric Modicon Tm221ce16r Firmware

Crítica 9.8 Sin autenticación

Prioridad
74
CVSS 3.1
9.8
EPSS
—
Requiere autenticación
No
Publicada
6 abr 2017
Actualizada
17 jun 2026
Categoría
Firmware · Equipo de red
Debilidad (CWE)
CWE-798, CWE-321
SSVC (CISA)
Explotación: ninguna · Automatizable: sí · Impacto técnico: total
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Qué pasa

Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

Texto original de NVD, en inglés. La traducción y el resumen en español llegan pronto.

Qué hacer

  1. Aplica la actualización de seguridad del fabricante para Modicon Tm221ce16r Firmware.
  2. Se explota sin autenticación: si no puedes parchear ya, limita el acceso desde Internet al servicio afectado.

Productos afectados (CPE)

FabricanteProductoVersiones
schneider-electricmodicon_tm221ce16r_firmware1.3.3.3
schneider-electricsomachine1.4