CVE-2018-11421Moxa Oncell G3150-hspa Firmware
Crítica 9.8 Sin autenticación
- Prioridad
- 74
- CVSS 3.0
- 9.8
- EPSS
- —
- Requiere autenticación
- No
- Publicada
- 3 jul 2019
- Actualizada
- 17 jun 2026
- Categoría
- Firmware · Equipo de red
- Debilidad (CWE)
- CWE-319
- Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Qué pasa
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
Qué hacer
- Aplica la actualización de seguridad del fabricante para Oncell G3150-hspa Firmware.
- Se explota sin autenticación: si no puedes parchear ya, limita el acceso desde Internet al servicio afectado.
Productos afectados (CPE)
| Fabricante | Producto | Versiones |
|---|---|---|
| moxa | oncell_g3150-hspa_firmware | ≤ 1.6 |
| moxa | oncell_g3150-hspa-t_firmware | ≤ 1.6 |
Fuentes oficiales
Referencias
Enlaces publicados por las fuentes. Ábrelos con criterio.
- github.com Third Party Advisory