Amenazas en vivo

Todas las CVE / Phoenix Contact

CVE-2026-110021Phoenix Contact PLCnext Engineer

Media 6.9

Prioridad
41
CVSS 4.0
6.9
EPSS
—
Requiere autenticación
Sí
Publicada
4 nov 2026
Actualizada
12 nov 2026
Categoría
Aplicación · Multiplataforma
Debilidad (CWE)
CWE-347
SSVC (CISA)
Explotación: ninguna · Automatizable: no · Impacto técnico: parcial
Vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Qué pasa

PLCnext Engineer checks GSDX manifest reference digests but does not cryptographically verify the XML `SignatureValue` over canonicalized `SignedInfo`. An unauthenticated local attacker can modify signed GSDML content, update its manifest digest, retain the public certificate data, and leave an invalid nonempty `SignatureValue`. PLCnext Engineer prior to 2026.6 reports the package as `Valid` and selects the modified device description for import under the default policy.

Texto original de NVD, en inglés. La traducción y el resumen en español llegan pronto.

Qué hacer

  1. Aplica la actualización de seguridad del fabricante para PLCnext Engineer.

Productos afectados

Según el CNA que publicó la CVE. NVD todavía no cargó los CPE con versiones.

Fuentes oficiales

Referencias

Enlaces publicados por las fuentes. Ábrelos con criterio.