Amenazas en vivo

Todas las CVE / Asseco Poland S.A.

CVE-2025-9313Asseco Poland S.A. mMedica

Crítica 9.3 Sin autenticación

Prioridad
71
CVSS 4.0
9.3
EPSS
—
Requiere autenticación
No
Publicada
28 oct 2025
Actualizada
8 oct 2026
Categoría
Aplicación · Multiplataforma
Debilidad (CWE)
CWE-288
SSVC (CISA)
Explotación: ninguna · Automatizable: sí · Impacto técnico: total
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Qué pasa

An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.

Texto original de NVD, en inglés. La traducción y el resumen en español llegan pronto.

Qué hacer

  1. Aplica la actualización de seguridad del fabricante para mMedica.
  2. Se explota sin autenticación: si no puedes parchear ya, limita el acceso desde Internet al servicio afectado.

Productos afectados

Según el CNA que publicó la CVE. NVD todavía no cargó los CPE con versiones.

Fuentes oficiales

Referencias

Enlaces publicados por las fuentes. Ábrelos con criterio.